Kamis, 08 Desember 2011

KYORITSU INDONESIA

PT. Tridinamika Jaya Instrument adalah perusahaan yang bergerak di bidang penjualan Measuring Instrument.
Kami menjual produk Kyoritsu. Inilah beberapa produk Kyoritsu yang kami jual :


    Kyoritsu adalah produk measuring instrument yang  memiliki banyak tipe,yaitu:
    Clamp Meters,Combi Testers,Digital Multimeter,Earth Testers,
    Insulation Testers,Logger,Loop PFC,
    Multi Function Testers,Portable Appliance Testers,Power Meters,RCD Testers,
    Sensor,Multi-trans,Clamp Adaptor,dan Voltage Testers.
    Setiap tipe memiliki keunggulan masing-masing :

1. Clamp Meters
    2413R Leakage Clamp Meters
 

 DESCRIPTION


•     Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires              (3  phases) together for leakage current measurement.
•     True RMS enables an accurate measurement for distorted waveforms.
•     Measurement from mA up to
      AC 1000A
•     Frequency filter switch to eliminate the effect of the harmonics.
•     2 way analogue output terminal:
      AC current detected by transformer jaws is converted to AC and DC voltage. Output cord            model 7073  (option) is used for monitoring waveform with an oscilloscope or for connecting to a recorder.

2. Combi Tester
    6050 Combi Tester

DESCRIPTION


•     Kew Combitester provides the ultimate in Microprocessor technology offering Loop and RCD tests  with a comprehensive memory and downloading test   results.
•     LOOP Impedance 200/2000Ω range measurement is carried out using a test current of 15mA. This current will not trip RCD’s rated at 30mA or greater.
•     High resolution for low Loop Impedance (resolution of 0.01Ω) on 20Ω range.
•     Direct reading of Prospective Short Circuit Current (PSC) and earth fault current.
•     RCD tests at 0 and 180 degree phase angle switch permit quick tests and consistent readings.
•     Test of a large kind of RCD's Standard, Selective, AC and A (DC sensitive breakers).
•     Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.
•     RCD Ramp test in order to indicate the actual tripping current of RCD.
•     Contact Voltage Reading (UC). with two selectable contact voltage limits
•     Visual indication of correct wiring status and automatic lock-out if test resistors overheats.
•     Designed to IEC 61010-1, IEC 61557 and high protection degree IP54.
•     The stored data can be transferred to PC via Optical Adapter Model 8212-RS232C and 8212-USB.

3. Digital Multimeter
    1062 Digital Multimeter

  
DESCRIPTION

High Accuracy, High Performance and Reliable Measurements
•     0.02% basic DC accuracy
•     Large display with 50,000 counts
•     Dual display for double indication for AC and DC, V and Hz, etc.
•     True-RMS Measurements AC and AC+DC
•     Wide AC Frequency bandwidth from 10Hz to 100kHz *
•     True-RMS or MEAN value detection mode can be selected *
•     Fast Peak Hold response time of 250µs
•     Low-pass filter for motor drive measurements *
•     Low Power Ω for resistance measurements on sensible electronic circuits by a low and safe test current *
•     User calibration function
* Only for KEW 1062
Safety design for industrial use
•     Complies with IEC 61010-1 CAT.III 1000V, CAT.IV 600V
•     Terminal shutter to prevent incorrect test leads' insertion in current terminals
•     Very wide operating temperature range from -20 to 55ºC
Reliable support for data management
•     Large data internal memory
KEW 1062: 10,000 data (logging), 100 data (manual)
KEW 1061: 1,000 data (logging), 100 data (manual)
•     Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)

4.Earth Testers
   4105A Earth Testers


DESCRIPTION


•    Dust and drip proof.(designed to IEC 529 IP54)
•     In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories.
(unit can be hung from the neck for simplified measurement)
•    Designed to meet IEC 61010-1 safety standard.
•    Capable of measuring earth voltage.
•    Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance.
•    Small and lightweight. Shock resistant new case material.
•    2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.

5. Insulation Testers
    3007A Digital Insulation / Continuity Tester
 

DESCRIPTION

•     3 functions in one unit, insulation test with 4 voltage ranges, continuity test, AC voltage measurement
•     200mA measuring current on continuity testing
•     Comparator function with PASS / FAIL and buzzer
•     0Ω adjustment at continuity measuring range
•     Memory function up to 99 data
•     Backlight LCD provides easy reading in dark locations
•     Safety lock system prevents an erroneous operation on 500 and 1000 Volt ranges
•     Safety standard IEC 61010-01 CAT.III 600V

6. Logger
    5001 Leak Logger



DESCRIPTION


THE LEAKAGE CURRENT IS RECORDED BY 3CH INPUT
60,000 DATA IS RECORDED
60,000 data is recorded when 1ch is used and when three all channels are used, 20,000 data is recorded for each channel
Continuous measurement time
About 40 days

Data where it doesn’t disappear even if battery is consumed
Data doesn’t disappear by using the nonvolatile memory when the battery is consumed and the battery is exchanged. (warranty for 10 years)

Battery residual display
The battery state is displayed by 4 stages. (When blinking is displayed, it is possible to measure for about one day)

The present time, recording intervals, the start of recording, the recording method, the name of monitoring site and the comment can be set by using  supplied software.

7. Loop-PFC-PSC
    4118A LOOP / PSC Tester


DESCRIPTION


•     Custom microprocessor controlled for highest accuracy and reliability.
•     3 LEDs for checking correct wiring status.
•     15mA LOOP measurement:
LOOP impedance 2000Ω range measurement is carried out with low test current (15mA).
The current will not cause tripping out involved RCD even the one with the lowest nominal differential current (30mA).
•     Direct reading of Prospective Short Circuit Current (PSC).
•     Safe voltage measurement function.
•     Large custom digital display readout on all models.
•     Measure low loop resistances(resolution of 0.01Ω)
•     Automatic lock-out if test resister overheats.
•     Large custom digital display readout .
•     Visual indication of reversed phase and neutral wiring at socket.
•     Designed to IP54 Rating
•     Complies with IEC 61557

8. Multi Function Testers
    6010B Multi Function Testers



DESCRIPTION



Continuity:
20/200Ω
200mA Test Current
•     Insulation:
500/1000V, 20/200MΩ
1mA Rated Test Current
•     Loop Impedance:
20/2000Ω
15mA Test Current at 2000Ω (No RCD Trip)
•     RCD:
10/30/100/300/500mA
x1/2, x1, Fast Trip(40ms), DC, Auto Ramp
•     Test of a large kind of RCD's:
Standard, Selective, AC and A
(DC sensitive breakers)
•     Uc(Contact Voltage): 100V
•     Designed to IEC 61010-1, IEC 61557
•     Data Memory:300 measured results
•     The stored data can be transferred to PC via Optical Adaptor Model 8212-USB or 8212-RS232C.

9. Portable Appliance Testers
    6201A Portable Appliance Tester



DESCRIPTION


 The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of ClassI and ClassII appliances. And also can measure the mains voltage.
Readings are displayed on a large liquid crystal display (LCD) below which are four LEDs which unambiguously display a pass or fail indication for threshold values dictated by AS/NZS 3760.   
This instrument is suitable for performing tests as required by the following standards.
AS/NZS 3760:2003 In-service safety inspection and testing of electrical equipment.

10. Power Meters 
      6310 Power Meter


DESCRIPTION



•     Can measure Flicker in accordance to IEC 61000-4-15 and EN50160 standards
Using our Flicker sensor, available as optional accessory, Pst value (short term
severity in 10 minutes value) and the Plt value (long term severity in 2 hours value)
can be measured.   
•     12 kinds of Power Measurements for Power Control and Applicable to
Power Quality Control including Harmonics Analysis.
•     One click easy-to-use operation helps complicated setting and
processing of large data
through the setting / analyzing software provided as accessory.
•     Direct communication with PC via USB cable
•     Built-in Input / Output Function of external signal enables the
signal transmission to alarms.
•     2-way power supply by AC and Battery, and Nickel hydrogen battery
usable with rechargeable function.
•     Pull / Insert of CF card possible whenever on recording under the
function of memory backup device.
•     Can monitor insulation at leakage current by using optional leak clamp sensors.
•     Built-in Print Screen Function enables to record display screen
(Records 512 screens by using CF card: 1 screen 40KB).
•     Can display Waveform and Vector, and can confirm the wiring connection, too.
•     Complies fully with International Safety Standards IEC 61010-1 CAT.III 600V.


11. RCD Testers
      5410 RCD Testers


DESCRIPTION



•     Measurement of RCD trip time
Conducting testing of rated residual non-operating currents at × 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges.
•     Measurement of trip out current
Measuring trip out current by varying current automatically.
•     Remote Test
Enabling a user to hold the Test Leads with his both hands by locking the Test Button.
Measurement will automatically start when the main voltagedetected.
•     Voltage Measurement
Carrying out a constant measurement of voltage in the stand-by mode at each Range.
•     Auto-detection of Contact voltage
Detecting the voltage to earth of Earth electrodes or Protective conductors during RCD test -
when applying test currents at measurement using EARTH in   order to prevent electrical shocks
caused by the damaged earth. Measurement will be ceased at AC50V more.
•    Dust- and Water-proof
Dust- and Water-proof construction (designed to IEC 60529 IP54).
•     Backlight
Facilitating working at dimly illuminated locations.


12. Sensor,Multi-trans,Clamp Adaptor 
      8123 Load Current Clamp Sensor




 FEATURES


Conductor size Φ55
Rated current AC 1000A
Output voltage AC 500mV/1000A (AC 0.5mV/A)
Accuracy |±2.0%rdg±0.3mV (50/60Hz)
|±3.0%rdg±0.5mV (40Hz~1kHz)
Withstand voltage AC 5350V for 5 seconds
Cable length Approx. 2m
Output connector MINI DIN 6pin
Operating temperature ranges 0~40ºC, less than 85% RH (without condensation)
Output impedance Approx. 1.5Ω
Applicable standards IEC 61010-1:2001,
IEC 61010-2-032:2002,
CAT.III 600V pollution degree 2
Dimensions 170(L) x 105(W) x 48(D) mm
Weight Approx.360g
Accessories 9094 (Portable case), Instruction manual, Cable marker
Option 7146 (Banana Φ4 adjuster plug)
7185 (Extension Cable)

 13. Voltage Tester
       1700 Voltage Tester

DESCRIPTION

•     Designed to meet international safety standards
IEC 61243-3/IEC 61010-1
Measurement Category (CAT.) IV 600V
•     Self-Diagnostic test
•     AC and DC voltage tests up to 690V with LED
•     Polarity indication
•     Single-pole phase test
•     Phase rotation test
•     Double molding gives comfortable grip
•     Continuity test
•     Auto-power ON/OFF
•     Pen light for illuminating measurement points
•     Variable distance in socket, 16.7mm or 19.0mm
•     Variable probe Tips, 1.6mm or 4mmφ
•     Probe cover protects user and probe Tips
•     IP65 (IEC 60529)

Untuk informasi dan pemesanan hubungi contact kami.

Nama Perusahaan
: PT. TRIDINAMIKA JAYA INSTRUMENT
Industrial | Electrical | General Supplier | Education | Instrumentation
Alamat : Jalan Boulevard Raya Blok BA 3 No 15.
Gading Serpong – Tangerang 15810 , Jakarta, Indonesia.

Phone
62-21-546 7617, 546 7618, 5421 2399, 5421 2402, 5422 0925
Fax
62-21-546 7617.
Email
tridi@tridinamika.com
Website
www.tridinamika.co.id | www.tridinamika.com